NEW QUESTION # 38
Which of the following tend to cause sheath damage during cable pulling?
- A. FMC/FMT
- B. EMT/ENT
- C. RMC/IMC
Answer: A
NEW QUESTION # 39
Which type of tester includes a set of modular plugs?
- A. Tone generator
- B. Multimeter
- C. Inductive amplifier
- D. Cable-end locator kit
Answer: D
NEW QUESTION # 40
Which of the following is used to measure the length of a 4-pair cable?
- A. Cable-end locator kit
- B. Tone generator
- C. Pair scanner
- D. Time domain reflectometer (TDR)
Answer: D
NEW QUESTION # 41
When bonding a shielded twisted-pair cable system, which of the following must be ensured to comply with proper grounding and bonding practices?
- A. The cable shield is bonded to a non-conductive anchor to prevent ground loops
- B. The drain wire or shield foil is securely bonded to the connecting hardware or patch panel that is connected to the TGB/TMGB
- C. Only the outer jacket is stripped back to expose the shield at the connector
- D. The shield is folded back outside of the connector for easy visual inspection
Answer: B
NEW QUESTION # 42
If the specified diameter for a conduit run is 25 mm (1 in), but an installer only has 20 mm (¾ in) conduit available, what is the MOST appropriate BICSI-recommended solution?
- A. Use the 20 mm conduit but reduce the cable count
- B. Increase the tension while pulling to fit cables into the 20 mm conduit
- C. Combine multiple 20 mm conduits side-by-side
- D. Obtain the specified 25 mm conduit or larger
Answer: D
NEW QUESTION # 43
Which of the following is a critical requirement for a Telecommunications Enclosure (TE) as opposed to a Telecommunications Room (TR)?
- A. The TE must hold all building cross-connects for the backbone cabling
- B. The TE requires dedicated electrical power panels for distribution
- C. The TE must have active electronics fully protected by a 2-hour rated firewall
- D. The TE can be secured to a wall or ceiling and is typically smaller, without dedicated HVAC
Answer: D
NEW QUESTION # 44
What type of coaxial cable is used for video backbone distribution?
- A. RG 58
- B. Series 6
- C. RG 59
- D. Series 11
Answer: D
NEW QUESTION # 45
Which of the following is a floor serving space that serves as a point of termination for horizontal and backbone cables?
- A. EF
- B. TE
- C. TR
- D. ER
Answer: C
NEW QUESTION # 46
If a conduit run between two pull boxes has two 90-degree bends and measures 23 m (75 ft) total in length, what is the BEST way to comply with BICSI recommendations if you need to add a third 90-degree bend?
- A. Lubricate the conduit heavily and pull the cable in one continuous run
- B. Use a flexible metallic conduit for the final bend
- C. Add an appropriately placed pull box or intermediate point
- D. Replace the entire run with larger conduit
Answer: C
NEW QUESTION # 47
What is the recommended minimum amount of aisle space between and around equipment?
- A. 0.6 m (2')
- B. 1.52 m (5')
- C. 1 m (3.3')
- D. 1.2 m (4')
Answer: C
NEW QUESTION # 48
What method of transmission is used to transmit signals during a telephone call?
- A. Simplex
- B. Full duplex
- C. Half-duplex
Answer: B
NEW QUESTION # 49
What is the bend radius requirement for optical fiber cable when the cable is at rest?
- A. 10 times the cables outside diameter
- B. 20 times the cables outside diameter
- C. 15 times the cables outside diameter
Answer: A
NEW QUESTION # 50
The information transmitted by an ICT system can originate in two fundamental forms:
- A. Analog and digital
- B. Light and sound
- C. Synchronous and asynchronous
- D. Progressive and regressive
Answer: A
NEW QUESTION # 51
What is the primary purpose of firestopping?
- A. Restore the barrier's original load-bearing capacity
- B. Increase a facilities ability to detect fires
- C. Suppress fires before they can spread
- D. Reestablish the barrier's fire rating
Answer: D
NEW QUESTION # 52
What is the minimum number of consolidation points that should serve an open office furniture cluster?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION # 53
A category 8 cable is terminated into category 6A outlets with category 5e patch cords. What is the maximum supported performance level?
- A. Category 6A
- B. Category 5e
- C. Category 7
- D. Category 8
Answer: B
NEW QUESTION # 54
A BICSI Installer 2 must verify continuity on all conductors of a multi-pair backbone copper cable. Which tool is the MOST efficient for accomplishing this?
- A. A standard VOM (Volt-Ohm Meter)
- B. A cable certification tester with pair continuity functionality
- C. A tone generator with an inductive amplifier
- D. Time Domain Reflectometer (TDR)
Answer: B
NEW QUESTION # 55
If the situation requires, a conduit should be terminated _______ the plywood backboard?
- A. Through
- B. Above
- C. Below
Answer: A
NEW QUESTION # 56
......