NEW QUESTION # 38
Which of the following tend to cause sheath damage during cable pulling?

  • A. FMC/FMT
  • B. EMT/ENT
  • C. RMC/IMC

Answer: A


NEW QUESTION # 39
Which type of tester includes a set of modular plugs?

  • A. Tone generator
  • B. Multimeter
  • C. Inductive amplifier
  • D. Cable-end locator kit

Answer: D


NEW QUESTION # 40
Which of the following is used to measure the length of a 4-pair cable?

  • A. Cable-end locator kit
  • B. Tone generator
  • C. Pair scanner
  • D. Time domain reflectometer (TDR)

Answer: D


NEW QUESTION # 41
When bonding a shielded twisted-pair cable system, which of the following must be ensured to comply with proper grounding and bonding practices?

  • A. The cable shield is bonded to a non-conductive anchor to prevent ground loops
  • B. The drain wire or shield foil is securely bonded to the connecting hardware or patch panel that is connected to the TGB/TMGB
  • C. Only the outer jacket is stripped back to expose the shield at the connector
  • D. The shield is folded back outside of the connector for easy visual inspection

Answer: B


NEW QUESTION # 42
If the specified diameter for a conduit run is 25 mm (1 in), but an installer only has 20 mm (¾ in) conduit available, what is the MOST appropriate BICSI-recommended solution?

  • A. Use the 20 mm conduit but reduce the cable count
  • B. Increase the tension while pulling to fit cables into the 20 mm conduit
  • C. Combine multiple 20 mm conduits side-by-side
  • D. Obtain the specified 25 mm conduit or larger

Answer: D


NEW QUESTION # 43
Which of the following is a critical requirement for a Telecommunications Enclosure (TE) as opposed to a Telecommunications Room (TR)?

  • A. The TE must hold all building cross-connects for the backbone cabling
  • B. The TE requires dedicated electrical power panels for distribution
  • C. The TE must have active electronics fully protected by a 2-hour rated firewall
  • D. The TE can be secured to a wall or ceiling and is typically smaller, without dedicated HVAC

Answer: D


NEW QUESTION # 44
What type of coaxial cable is used for video backbone distribution?

  • A. RG 58
  • B. Series 6
  • C. RG 59
  • D. Series 11

Answer: D


NEW QUESTION # 45
Which of the following is a floor serving space that serves as a point of termination for horizontal and backbone cables?

  • A. EF
  • B. TE
  • C. TR
  • D. ER

Answer: C


NEW QUESTION # 46
If a conduit run between two pull boxes has two 90-degree bends and measures 23 m (75 ft) total in length, what is the BEST way to comply with BICSI recommendations if you need to add a third 90-degree bend?

  • A. Lubricate the conduit heavily and pull the cable in one continuous run
  • B. Use a flexible metallic conduit for the final bend
  • C. Add an appropriately placed pull box or intermediate point
  • D. Replace the entire run with larger conduit

Answer: C


NEW QUESTION # 47
What is the recommended minimum amount of aisle space between and around equipment?

  • A. 0.6 m (2')
  • B. 1.52 m (5')
  • C. 1 m (3.3')
  • D. 1.2 m (4')

Answer: C


NEW QUESTION # 48
What method of transmission is used to transmit signals during a telephone call?

  • A. Simplex
  • B. Full duplex
  • C. Half-duplex

Answer: B


NEW QUESTION # 49
What is the bend radius requirement for optical fiber cable when the cable is at rest?

  • A. 10 times the cables outside diameter
  • B. 20 times the cables outside diameter
  • C. 15 times the cables outside diameter

Answer: A


NEW QUESTION # 50
The information transmitted by an ICT system can originate in two fundamental forms:

  • A. Analog and digital
  • B. Light and sound
  • C. Synchronous and asynchronous
  • D. Progressive and regressive

Answer: A


NEW QUESTION # 51
What is the primary purpose of firestopping?

  • A. Restore the barrier's original load-bearing capacity
  • B. Increase a facilities ability to detect fires
  • C. Suppress fires before they can spread
  • D. Reestablish the barrier's fire rating

Answer: D


NEW QUESTION # 52
What is the minimum number of consolidation points that should serve an open office furniture cluster?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 53
A category 8 cable is terminated into category 6A outlets with category 5e patch cords. What is the maximum supported performance level?

  • A. Category 6A
  • B. Category 5e
  • C. Category 7
  • D. Category 8

Answer: B


NEW QUESTION # 54
A BICSI Installer 2 must verify continuity on all conductors of a multi-pair backbone copper cable. Which tool is the MOST efficient for accomplishing this?

  • A. A standard VOM (Volt-Ohm Meter)
  • B. A cable certification tester with pair continuity functionality
  • C. A tone generator with an inductive amplifier
  • D. Time Domain Reflectometer (TDR)

Answer: B


NEW QUESTION # 55
If the situation requires, a conduit should be terminated _______ the plywood backboard?

  • A. Through
  • B. Above
  • C. Below

Answer: A