Released SolarWinds Hybrid-Cloud-Observability-Network-Monitoring Updated Questions PDF [Q88-Q103]

Share

Released SolarWinds Hybrid-Cloud-Observability-Network-Monitoring Updated Questions PDF

Hybrid-Cloud-Observability-Network-Monitoring Dumps and Practice Test (167 Exam Questions)

NEW QUESTION # 88
Which custom filter allows a user to view specific statistics about an entire network and its devices without having to navigate through the web console by single-device views?

  • A. flow navigator
  • B. NBAR2
  • C. flow alert
  • D. top 10 applications

Answer: A

Explanation:
The Flow Navigator in SolarWinds NetFlow Traffic Analyzer (NTA) is a powerful custom filter and analysis tool. It enables users to apply multiple filters to NetFlow data, allowing the visualization of specific statistics about the entire network or selected subsets, such as all traffic from a certain IP range or application. This approach eliminates the need to manually click through device-by-device views, instead providing comprehensive traffic analysis across the whole monitored environment through a single, customizable interface.
Reference:
" Use the Flow Navigator to apply multiple filters for viewing NetFlow data, enabling users to see traffic patterns for the entire network or specific subnets, applications, or endpoints without needing to open individual device pages. "
- (Network Performance Monitor Administrator Guide, Section: NetFlow Traffic Analysis)


NEW QUESTION # 89
Which method is used to add new UPS battery status statistics onto an existing node that does not have the default value polled?

  • A. custom statistics cannot be added to 3n existing node
  • B. update SolarWinds' MIB database
  • C. define custom statistic with universal device poller (UnDP)
  • D. create new custom device poller

Answer: C


NEW QUESTION # 90
In live mode, how frequently is log viewer data automatically refreshed?

  • A. 10 seconds
  • B. 10 minutes
  • C. 1 minute
  • D. 1 second

Answer: A


NEW QUESTION # 91
To which port does Log Analyzer forward secure syslog when a log forwarding custom rule action is set to TCP?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
SolarWinds Log Analyzer supports secure syslog forwarding using the TCP protocol. The industry standard and the default port used for secure syslog (Syslog over TLS/TCP) is port 6514. This is referenced in SolarWinds documentation where it specifies:
" For secure syslog forwarding, Log Analyzer uses TCP port 6514, which is the default for syslog over TLS, as defined by RFC 5425. " This ensures that log data is encrypted during transmission, enhancing security over the default UDP port 514 (which is used for non-secure syslog).
References:
Log Analyzer Administrator Guide, " Syslog Forwarding "
RFC 5425 (referenced in SolarWinds documentation)


NEW QUESTION # 92
Which NetFlow component can be applied to an interface to track IPv4 traffic?

  • A. flow monitor
  • B. flow sampler
  • C. flow record
  • D. flow exporter

Answer: A

Explanation:
In NetFlow (especially Flexible NetFlow on Cisco devices), a flow monitor is applied to an interface to track and collect information about IPv4 (or IPv6) traffic. The flow monitor references a flow record and a flow exporter. The monitor itself is the entity configured on an interface to start the flow tracking process.
Reference:
" To enable traffic flow monitoring, apply a flow monitor to an interface. The flow monitor defines which flows are captured and how they are exported for analysis. "
- (Network Performance Monitor Administrator Guide, NetFlow Setup and Monitoring section)


NEW QUESTION # 93
It is taking longer than normal for a single mission critical node to poll for data. Where would the polling interval for the node be changed?

  • A. Node Details Summary > Edit Node > Polling
  • B. Settings > All Settings > Polling Settings
  • C. Node Details Summary > Resources > Memory
  • D. Settings > All Setting > Core Thresholds

Answer: A

Explanation:
To change the polling interval for a specific node, navigate to the Node Details Summary, then choose "Edit Node." In the polling section, you can configure how often SolarWinds polls this node for status and statistics. This is the correct place for per-node polling interval adjustments.
The global polling settings under "Settings > All Settings > Polling Settings" (option D) affect all nodes, not an individual node.
References:
NPM Administrator Guide: Changing Node-Specific Polling Intervals


NEW QUESTION # 94
Which two of the following actions can be taken to resolve unknown flow traffic events? (Choose two.)

  • A. Enable automatic addition of flow sources.
  • B. Ensure flow-enabled devices send data to appropriate port.
  • C. Configure devices to send all flow data.
  • D. Add the devices and interfaces to SolarWinds' database.

Answer: B,D


NEW QUESTION # 95
If a NetFlow collector service is showing a "down" status, which two of the following steps are possible troubleshooting options? (Choose two.)

  • A. Start or restart SolarWinds' collector service.
  • B. Delete and re-add NetFlow collector service.
  • C. Start or restart SolarWinds' NetFlow service from Orion service manager.
  • D. Confirm the database connection is up and server has free resources.

Answer: C,D


NEW QUESTION # 96
Which method is used to add new UPS battery status statistics onto an existing node that does not have the default value polled?

  • A. update SolarWinds' MIB database
  • B. custom statistics cannot be added to an existing node
  • C. define custom statistic with universal device poller (UnDP)
  • D. create new custom device poller

Answer: C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
The Universal Device Poller (UnDP) allows administrators to define custom SNMP OIDs for statistics (like UPS battery status) that are not natively polled. You can assign a new UnDP to an existing node to monitor additional values such as UPS battery status, provided the device supports the necessary OID.
Reference:
"Use the Universal Device Poller to assign additional custom statistics, such as UPS battery status, to any node that supports the relevant SNMP OID."
- (Network Performance Monitor Administrator Guide, Universal Device Poller section)


NEW QUESTION # 97
NetFlow and CBQoS monitoring can be disabled through web console settings. If NetFlow monitoring is disabled for a node or interface, the data collection is stopped. Which two of the following statements are true regarding disabling NetFlow monitoring? (Choose two.)

  • A. enabling and disabling flow collection can result in gaps within NTA graphs
  • B. historical data is removed from the database
  • C. historical data is retained within the database
  • D. enabling and disabling flow collection will not cause gaps within NTA graphs

Answer: A,C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Disabling NetFlow/CBQoS stops flow data collection, resulting in gaps in graphs during the disabled period (A). However, historical data collected prior to disabling is retained in the database (C), so you can still view past flow information.
Reference:
NTA Administrator Guide, "Enabling/Disabling Flow Collection and Data Retention,"
"Disabling monitoring creates data gaps but does not delete historical flow records."QUESTION


NEW QUESTION # 98
Which two of the following actions are recommended for more precise forecasting of capacity trends on critical devices? (Choose two.)

  • A. Set calculation methods to use average daily values.
  • B. Monitor devices with platform agents.
  • C. More historical data used in calculations.
  • D. Set warning and critical thresholds to lower percentages.

Answer: A,C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
SolarWinds capacity forecasting accuracy improves when:
More historical data is used: The more historical data points included in calculations, the better the forecasting model will perform.
Using average daily values for calculations: This smooths out anomalies and provides a more accurate trend, as recommended in the documentation:
"To improve the precision of capacity forecasting, use as much historical data as possible and set calculations to use average daily values." Monitoring with platform agents or adjusting thresholds affects alerting, not trend accuracy.
References:
NPM Administrator Guide: Capacity Forecasting Best Practices


NEW QUESTION # 99
Several resources are showing duplicate flow data. What is the most likely cause?

  • A. SolarWinds' NetFlow service needs to be restarted
  • B. source devices are configured to export flow data on ingress and egress
  • C. interfaces have duplicate entries in flow sources management
  • D. interfaces in flow sources management are set to drop

Answer: B


NEW QUESTION # 100
It is taking longer than normal for a single mission critical node to poll for data. Where would the polling interval for the node be changed?

  • A. Node Details Summary > Edit Node > Polling
  • B. Settings > All Settings > Polling Settings
  • C. Node Details Summary > Resources > Memory
  • D. Settings > All Setting > Core Thresholds

Answer: A

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To change the polling interval for a specific node, navigate to the Node Details Summary, then choose "Edit Node." In the polling section, you can configure how often SolarWinds polls this node for status and statistics. This is the correct place for per-node polling interval adjustments.
The global polling settings under "Settings > All Settings > Polling Settings" (option D) affect all nodes, not an individual node.
References:
NPM Administrator Guide: Changing Node-Specific Polling Intervals


NEW QUESTION # 101
The web console is showing the status of a network router as "down", however the node is up and running.
Which two of the following causes could be creating the issue? (Choose two.)

  • A. agent connection status with the polling engine is " down "
  • B. ICMP is blocked between the device and the polling engine
  • C. SNMP is blocked between the device and the polling engine
  • D. router is configured as a parent in a node dependency

Answer: B,C

Explanation:
If the web console shows a router as "down" but it is actually operational:
ICMP is blocked: If the polling engine cannot ping the device, it will be reported as down.
SNMP is blocked: If SNMP polling fails (for devices polled via SNMP), detailed data and status cannot be retrieved, resulting in a down state.
Agent connection issues may apply for agent-based monitoring but are not typical for network routers. Node dependency configuration could affect child node status display but would not cause the parent node to show
"down".
Reference:
NPM Administrator Guide, "Troubleshooting Node Status - Down State Causes"


NEW QUESTION # 102
Which tool is used to establish flow alerts?

  • A. flow alert wizard
  • B. create a flow alert panel
  • C. create alert flows
  • D. manage flow alert pane

Answer: B


NEW QUESTION # 103
......

Hybrid-Cloud-Observability-Network-Monitoring Exam Dumps Pass with Updated 2026 Certified Exam Questions: https://www.practicematerial.com/Hybrid-Cloud-Observability-Network-Monitoring-exam-materials.html